AHC812

■  Digital time switch with weekly program  and day cycle
■ 44 memory locations
  ●  Can Switching preselection
  ●  Can manually to control on-off for 1 times
  ●  Can manually to control on-off for Permanent
■   Language
  ● English
  ● Portugal
  ● Italy
  ● Spain
  ● Germany
  ● France
■  Automatic summer/winter time
  ● EUROPE
  ● Great Britain
  ● U.S.A/Canada
  ● FREE
■  PIN Code
  ●  4 Bit number
■  Screw terminals
■ Preset date and time
  ●  LCD Display
  ●  Display year/month/day/hour/minute
■  Built-in lithium battery, and travel time as usual after power failure
  ●  Fully operable without mains connection

AHC811
■  44 Memory pulse program
  ● Adjustable pulse duration 1s~59s
■  1 Channel
■  18 Cycle program
■  Random or Holiday program

AHC822
■  44 Memory pulse program
  ● Adjustable pulse duration 1s~59s
■  2 Channel
■  18 Cycle program
■  Random or Holiday program

Technical Data

Product Type AHC810-220/50Hz AHC811-220/50Hz AHC812-220/50Hz AHC822-220/50Hz AHC810-220/60Hz AHC811-220/60Hz AHC812-220/60Hz AHC822-220/60Hz
Operating voltage 220V AC
Frequency 50Hz 60Hz
Width 2 modules
Installation type Din rail
Terminal  Quantity 5 8 5 8
Type of contact Changeover contact
Switching output Phase-independent
Method of connection terminal Screw terminals
Power reserve 4 years
Switching capacity at
250 V AC, cos φ = 1
16A
Switching capacity at
250 V AC, cos φ = 0,6
10A
Incandescent/halogen lamp load 230V 2600W
Energy saving lamps 170W
LED lamp < 2 W 30W
LED lamp 2–8 W 100W
LED lamp > 8 W 120W
Fluorescent lamp load (electronic ballast) 650W
Fluorescent lamp load (conventional) not corrected 1000VA
Fluorescent lamp load (conventional)
series-corrected
1000VA
Fluorescent lamp load (conventional)
parallel-corrected
730 VA 80uF 
Time accuracy at 25 °C typical ± 2 s/day (quartz)
Consumed power 4VA 7.5VA 4VA 7.5VA
Test approval CE
Type of protection IP 20
Protection class II according to EN 60 730-1
Housing and insulation material High-temperature resistant, self-extinguishing thermoplastic
Work  temperature -10 ~ +50 °C (non-icing
Ambient humidity 3585RH

Product Type AHC810-110/50Hz AHC811-110/50Hz AHC812-110/50Hz AHC822-110/50Hz AHC810-110/60Hz AHC811-110/60Hz AHC812-110/60Hz AHC822-110/60Hz
Operating voltage 110V AC
Frequency 50Hz 60Hz
Width 2 modules
Installation type Din rail
Terminal  Quantity 5 8 5 8
Type of contact Changeover contact
Switching output Phase-independent
Method of connection terminal Screw terminals
Power reserve 4 years
Switching capacity at
250 V AC, cos φ = 1
16A
Switching capacity at
250 V AC, cos φ = 0,6
10A
Incandescent/halogen lamp load 230V 2600W
Energy saving lamps 170W
LED lamp < 2 W 30W
LED lamp 2–8 W 100W
LED lamp > 8 W 120W
Fluorescent lamp load (electronic ballast) 650W
Fluorescent lamp load (conventional) not corrected 1000VA
Fluorescent lamp load (conventional)
series-corrected
1000VA
Fluorescent lamp load (conventional)
parallel-corrected
730 VA 80uF 
Time accuracy at 25 °C typical ± 2 s/day (quartz)
Consumed power 5VA 7.5VA 5VA 7.5VA
Test approval CE
Type of protection IP 20
Protection class II according to EN 60 730-1
Housing and insulation material High-temperature resistant, self-extinguishing thermoplastic
Work  temperature -10 ~ +50 °C (non-icing
Ambient humidity 3585RH

Product Type AHC810-12V AHC811-12V AHC812-12V AHC822-12V AHC810-24V AHC811-24V AHC812-24V AHC822-24V
Operating voltage 12V AC & DC 24V AC & DC
Frequency 50~60Hz for AC
Width 2 modules
Installation type Din rail
Terminal  Quantity 5 8 5 8
Type of contact Changeover contact
Switching output Phase-independent
Method of connection terminal Screw terminals
Power reserve 4 years
Switching capacity at
250 V AC, cos φ = 1
16A
Switching capacity at
250 V AC, cos φ = 0,6
10A
Incandescent/halogen lamp load 230V 2600W
Energy saving lamps 170W
LED lamp < 2 W 30W
LED lamp 2–8 W 100W
LED lamp > 8 W 120W
Fluorescent lamp load (electronic ballast) 650W
Fluorescent lamp load (conventional) not corrected 1000VA
Fluorescent lamp load (conventional)
series-corrected
1000VA
Fluorescent lamp load (conventional)
parallel-corrected
730 VA 80uF 
Time accuracy at 25 °C typical ± 2 s/day (quartz)
Consumed power 4VA 7.5VA 4VA 7.5VA
Test approval CE
Type of protection IP 20
Protection class II according to EN 60 730-1
Housing and insulation material High-temperature resistant, self-extinguishing thermoplastic
Work  temperature -10 ~ +50 °C (non-icing
Ambient humidity 3585RH

Structure

Connection